Alternator Rotor - magnet discs ARE NOT identical in arangement

Text mentions that the magnet discs are identical regarding magnet arrangement. In consequence, magnets facing each other would not be of different poles. Or am I getting something wrong? Addionally, it is described differently further down in the text.

In general, the importance of arranging the magnets could is not highlighted enough and should be described further.

Edited Feb 28, 2023 by linus ernix